Page 26 hot water performance reheat coils data the following performance data represents the 1 row hot water and steam reheat coils that are available on fan coil units in conjunction with a 2 3 or 4 row cooling coil.
Trane fan coil units pdf.
When you need it figure 1.
With the large airflow volume design these models can increase room ventilation frequency and balance room temperature distribution.
Trane paid particular attention on the sound level during the development of the unit.
See figure 1 for unit components.
Thus reducing by several db the overall sound level of the unit compared to the previous range.
Contact your local trane sales representative for more information.
Their supper thin design has the advantages of aesthetic outlook space saving and easy installation.
These units are used in high rise hotels and condominiums.
Each digit in the model number has a corresponding code that identifies specific unit options.
Chilled water fan coil units for district cooling.
The wall mounted option is low voltage using a factory wired transformer.
We have 1 trane unitrane fan coil manual available for free pdf download.
Trane blower coils factory packaged how you need it.
Not all options are available on all cabinet styles.
Fan coil units are available as 2 pipe with or without electric heat one hydronic circuit or 4 pipe two hydronic circuits.
Force flo units feature 2 pipe hydronic coils electric heat.
2020 trane unt prc028b en introduction vertical high rise fan coil units trane vertical high rise fa n coils are intended for single zone applications.
Unitrane fan coil following is a complete description of the unitrane fan coil model number.
Unitrane fan coil and force flo cabinet heaters units are single room units with load capabilities of 200 to 1200 cfm.
Digits 1 2 unit type.
Horizontal blower coil bchd model unit sizes 12 18 24 36 54 72 90 mbh knockouts in all four corners for hanger rods 1 2 3 hp ecm motor standard direct drive up to 2 5 inches total static eliminates the difficulties with belts control box options.
Installation operation maintenance trane unitrane fan coil installation operation maintenance 80 pages air terminal devices horizontal vertical and low vertical.
We work closely with engineers at the design sta ge to ensure opti mum use of the units within the hvac system.
Heating performance is based on 70 f 21 c entering air temperature 180 f 82 c entering hot water temperature with a 20 f.
Thanks to an ec motor and the zn control s continuous and variable speed control the fed fan coil can achieve exceptionally low sound levels without perceivable.